No. |
Test item |
Criterion |
1 |
Voltage |
Charging voltage |
DC:21V CC/CV(4.2V/1cell) |
Balance voltage for single cell |
|
2 |
Current |
Balance current for single cell |
|
Current consumption for single cell |
≤20μA |
Maximal continuous discharging current |
4A |
3 |
Overcharge Protection |
Over charge detection voltage |
4.28±0.025V |
Over charge detection delay time |
0.96S~1.4S |
Over charge release voltage |
4.08±0.025V |
4 |
Over-discharge Protection |
Over discharge detection voltage |
3.0±0.05V |
Over discharge detection delay time |
115~173mS |
Over discharge release voltage |
3.0±0.05V |
5 |
Over Current Protection |
Over current detection voltage |
0.62V |
Over current detection current |
10±2A(can adjust) |
Detection delay time |
7.2ms~11ms |
Release condition |
Cut load |
6 |
Short Protection |
Detection condition |
Exterior short circuit |
Detection delay time |
200-500us |
Release condition |
Cut load |
7 |
Resistance |
Protection circuitry |
≤50mΩ |
8 |
Temperature |
Operating temperature range |
-40~+85℃ |
Storage temperature range |
-40~+125℃ |
9 |
Size |
|
L46*W31*T4mm |