No. |
Test item
|
Criterion
|
1 |
Voltage |
Charging voltage |
CC/CV:Li-ion/Li-polymer(4.2V/cell),LiFePO4(3.6V/cell)
|
Balance voltage for single cell |
Li-ion:4.20 V±0.025V,LiFePO4:3.60V±0.025V |
2 |
Current |
Balance current for single cell |
0~300mA |
Current consumption for single cell |
≤20μA |
Maximal continuous charging and discharging current |
120A |
3 |
Over-charge Protection |
Over charge detection voltage |
3.8~4.4V(can adjust) |
Over charge detection delay time |
0.5~2.5S |
Over charge release voltage |
3.8~4.4V(can adjust) |
4 |
Over-discharge Protection |
Over discharge detection voltage |
1.9~3.1V(can adjust) |
Over discharge detection delay time |
50~300mS |
Over discharge release voltage |
1.9~3.1V(can adjust) |
5 |
Over-Current Protection |
Over current detection voltage |
0.6V |
Over current detection current |
100~500A |
Detection delay time |
1~50ms |
Release condition |
Cut load |
6 |
Short Protection |
Detection condition |
Exterior short circuit |
Detection delay time |
200-500us |
Release condition |
Cut load |
7 |
Resistance |
Protection circuitry(B- to P-) |
≤20mΩ |
8 |
Temperature |
Operating temperature range |
-40~+85℃ |
Storage temperature range |
-40~+125℃ |
9 |
Size |
|
L210*W188*T25mm |